SPECIFICATIONS
·
Model no. WA-8070E WA-1070E
Cooling capacity
8,000 BTU/hr 10,000 BTU/hr
Power consumption
900W 1125W
EER 8.9 8.9
Air volume (max. speed) 314m
3
/h 328m
3
/h
Noise level (H/L) 53.2/53.6
Humidity removal capacity 0.9 L/hr 1.1 L/hr
Power supply 115V/60Hz/1phase
Compressor rotary
Recommended room size 150-250 sq.ft. 200-300 sq.ft.
Refrigerant R410A
Fan speed 2
Timer 0.5 ~ 24 hours
Thermostat 62 ~88°F
Operating temperature (cool) 62 ~ 95°F
Operating temperature (dry) 55 ~ 95°F
Exhaust pipe 59 in
Net / Gross Weight 50.71 / 58.42 lbs
Unit Dimension 13.75 x 15 x 29.50
Package Dimension 15.43 x 21.34 x 30.71
* Data may vary for technical reasons; for greater precision, please refer to the rating label
located on the back of the unit.
Operating Conditions
The air conditioner must be operated within the temperature range indicated below:
MODE ROOM TEMPERATURE
COOL 17 ~ 35°C / 62 ~ 95°F
DRY 13 ~ 35°C / 55 ~ 95°F